• Point to Point Serial Architecture.
  • Software/Middleware transparent with legacy parallel SCSI.
  • 3Gb/S, Full duplex data transfer rate ( 6Gb/s ready soon)
  • Wide port, aggregated bandwidth by 4x Links
  • Expands to 16384 drivers with SAS fan-out expanders.
  • Up to 8M length of external cable.
  • SATA disk drives are fully compatible with SAS backplane.
  • Wdie range cost by GB, SATA for basic capability and SAS for high end.
ALNICO AL-8161J
| Datasheet  
16 bays 3U Rackmount SAS to SAS/SATA-II JBOD Subsystem

The Alnico 8161J is a 3U JBOD subsystems, supports up to 16 3,5" SAS or SATA-II drivers. The single miniSAS ( 4 x 3Gb/sec) ports provides connectivity and bandwidth to RAID subsystem or Sever, 2 x down stream mniSAS port for large capacity solutions requiring multiple cascaded more JBOD units.

Alnico 8161J is a full modular design, provides redundancy and hot swappable cooling fans, Power supplies can tolerate a main failure without interrupting service. All heath status can be reproting and monitoring through in-band SES. Firmware can be upgraded through in-band SAS or serial port.

Optional second JBOD expander module provide redundand datapaths t further help ensure availbility.

Highlights
  • Supports Serial Attached SCSI and SATA-II hard drives simultaneously.
  • 1 x High performance miniSAS connectors ( 4 x 3Gb/sec Links) for host per I/O board.
  • 2 x down-stream min-SAS supported, It can connect more SAS JBODs for capacity expansion.
  • Single SAS expander module supported, optional 2nd SAS expander module for Dual Redundant controller mode.
  • Heathy monitoring by In-band SES.
 
System Architecture
Single SAS expander module supported, optional 2nd SAS expander module for Dual Redundant controller mode.
Host Interface
1 x Up Stream miniSAS ( 4 x 3Gb links) per Expender board
Drive Interface
16 of SAS/SATA-II channel - by backplane ( SAS Disk supported only, when 2nd SAS expander module installed)

2 x miniSAS ( 4 x 3Gb Links) for expansion per Expender board

Monitors/Indicators

Through In band SAS

System status indication through LEDs and alarm buzzer
Environmental /Physical
Cooling
Two redundant, hot-swappable cooling modules with self-regulating speeds and wide range airflow design
Controlled by RAID controller automatically maintaining optimal ambient temperature
Electrical
Redundant by Dual 460W power supplies with PFC, load-sharing type, hot-swappable and cable-less design
AC Voltage 110-230 VAC /AC Frequency 50-60Hz
Temperature
Operating temperature: 5 to 35 degree C
Non-operating temperature: -40 to 60 degree C
Relative Humidity
20% to 80% non-condensing
Size and weight
Dimensions: 446.5mm(W) x 550mm(D) x 3U
Weight (w/o HDDs): 20.0kg
Technical Specifications